Installing Continental Pro Series

Installing Continental Pro Series

Chemical Corner – Washington Automated

 

 

 

Chemical Signals220v ac – Located in panel on back of machine.  These washers use the different segments for the different signals.  (Use Posts X5-2àX5-6)

I.E. – Post X5-2 is for Prewash, Post X5-3 is for the Wash bath, Post X5-3 is for Bleach bath, etc.

Use the post labeled X5-1 for supply common (220v ac).

 

Pump Power - Continental does not supply terminals for pulling power for external pumps.  You will need to find another source of power when installing Continentals.

 

Delivery Tubing - should be fixed to the white fittings on the back of the machine.

 

Programming – Pro Series Washers come with the PM or Premier Microprocessor.  There are a few varieties of this controller, but they are all fairly similar and straight forward.  All Continentals use the segment style to programming.

I did a copy/paste from the Continental website below. 

Find more information about these controls here: http://www.continentalgirbau.com/pro-seriesprogramming

Note:  You will need to sign up as a member to receive the manuals.

 

 

 

Premier Microprocessor Control
Continental’s Premier Microprocessor (PM) Control offers an easy-to-use programming system featuring 99 program selection options. Designed for flexibility, the control offers 20 pre-programmed and 79 user-programmable options to meet your unique on-premise laundry processing requirements. Everything from water temperature, wash action and fill levels, cycle time, delayed start, automatic cycle advance, automatic chemical injection, and extract speed are programmable to properly clean a variety of fabrics.